What size mini split do I need? Calculator and method
Every mini split decision starts with one number: the BTU rating your room actually needs. Get that right and the brand, the zones and the install fall into place. Get it wrong and you pay twice: once at checkout, then every month on the power bill.
Size your room
Fill in what you know. The result updates as you type.
Nothing is saved or sent anywhere
Example: 400 sq ft living room
Your load: about 9,000 BTU/h, rounded up to the next size that’s actually sold.
- Base for area9,000 BTU
Every size we cover
Guides in sizing & zones
By size
12,000 BTU mini splits: rooms they cool and the best picksA 12,000 BTU mini split comfortably handles a 450 to 550 sq ft room with 8 ft ceilings, which makes it right for most living rooms, large bedrooms and one-car garages. It's the most common size sold, so every brand makes one and prices are keenest here.
18,000 BTU mini splits: which rooms, which systems, when to go biggerAn 18,000 BTU mini split, also sold as 1.5 ton, handles 700 to 1,000 sq ft of open floor with 8 ft ceilings: a big living room, an open kitchen and dining area, or a two-car garage. It's the first size where a single head starts to struggle with rooms that have corners and doors.
24,000 BTU mini splits: the 2 ton size for big rooms and small homesA 24,000 BTU mini split, also sold as 2 ton, handles 1,000 to 1,500 sq ft of open floor with 8 ft ceilings: a great room, a large workshop, or a studio-style home. It's about the upper limit of what one wall head does well; past this, or with doors between rooms, you want more heads, not more capacity.
36,000 BTU mini splits: the 3 ton size, and when 30,000 is enoughA 36,000 BTU mini split, also sold as 3 ton, is the largest single-zone wall unit made and covers 1,500 to 2,500 sq ft of open floor: workshops, barns, big garages and vaulted great rooms. For a house with bedrooms, the same 3 tons should be a multi-zone system, not one head.
9,000 BTU mini splits: rooms they cool and when to go upA 9,000 BTU mini split (three-quarter ton) handles a 350 to 400 sq ft room with 8 ft ceilings: most bedrooms, home offices and small living rooms. It's also the smallest size most brands sell, so it's the right pick for nearly every room under 350 sq ft too.
6,000 BTU mini splits: who makes one, and when 9,000 is the real floorA 6,000 BTU mini split (half ton) is sized for rooms up to about 250 sq ft: nurseries, small bedrooms and home offices. Of the lines we cover only Mitsubishi makes one; every other brand starts at 9,000 BTU, which handles the same rooms with a little more cycling.
Multi-zone
3 zone mini splits: sizing three rooms and choosing the outdoor unitA 3 zone mini split is one outdoor unit feeding three indoor heads, each sized for its own room. A typical set is a 12,000 BTU head for the living area and two 9,000s for bedrooms, 30,000 BTU of heads on a 24,000 to 27,000 BTU condenser, because the three rooms rarely peak at the same time.
Dual zone mini splits: how to size two rooms on one outdoor unitA dual zone mini split is one outdoor unit feeding two indoor heads, each sized for its own room. Size the rooms separately, add the heads, and pick a condenser rated at or a little under the total; most makers allow the heads to exceed it by 20 to 30 percent because both rooms rarely peak at once.
Multi zone mini splits: how to size 2 to 5 rooms on one outdoor unitA multi zone mini split is one outdoor unit feeding two to five indoor heads, each sized for its own room. Size the rooms separately, add the heads, and choose the condenser from the maker's combination table; most allow the heads to total 20 to 30 percent more than the condenser's rating.
The short answer
Roughly 20 to 25 BTU per square foot for a normal room, then adjust for ceiling height, sun, insulation and climate, and round up to the next size you can buy. For a 400 sq ft room that's 9,000 to 12,000 BTU.
- Stuck between two sizes? Take the smaller one; it runs quieter and pulls more humidity out.
- Basements come off the table by about 15%, garages add 15% and sunrooms add 20%.
- Sizing a whole house with several heads? Pay for a Manual J instead of trusting square footage.
The number on the box is BTU per hour, and until you have it right, it’s the only spec that matters. Everything else about a mini split (the brand, the SEER2 rating, whether you install it yourself) is a conversation for afterwards. So we’ll give you that number and show how we got it, so you can argue with it.
The calculator above does the arithmetic in about thirty seconds. Below it sit the table it uses, the adjustments that move the result most, and the tie-breakers for a room that lands between two sizes.
Why the size matters more than the brand
An air conditioner is a dehumidifier that happens to cool. The cooling you feel on your skin is only half of comfort; the other half is the moisture the unit pulls out of the air as it runs. That takes time. A unit that’s too big for the room cools the air in a few minutes, hits its setpoint, and shuts off (or, on an inverter unit, throttles down to a trickle) before the coil has been cold long enough to wring the humidity out. You get a room that reads 72°F and feels like a basement.
Too small has the opposite problem, and it’s the one everyone worries about: the unit runs flat out on a July afternoon and never catches up. In practice it’s rarer than people think. Inverter compressors can run above their nominal rating for stretches, and most rooms aren’t at design conditions most of the time.
So a slightly small unit is more comfortable than a clearly large one. That runs against the instinct that says “go one size up to be safe”.
Mini split sizing, step by step
We start with the ENERGY STAR room air conditioner sizing table, which maps floor area to cooling BTU for a typical room with 8 ft ceilings, average insulation and mixed sun. It’s the most widely published sizing reference in the US and the one most installers reach for when they aren’t running a full load calculation.
| Floor area | Base BTU/h |
|---|---|
| 100–150 sq ft | 5,000 |
| 150–250 sq ft | 6,000 |
| 250–300 sq ft | 7,000 |
| 300–350 sq ft | 8,000 |
| 350–400 sq ft | 9,000 |
| 400–450 sq ft | 10,000 |
| 450–550 sq ft | 12,000 |
| 550–700 sq ft | 14,000 |
| 700–1,000 sq ft | 18,000 |
| 1,000–1,200 sq ft | 21,000 |
| 1,200–1,400 sq ft | 23,000 |
| 1,400–1,500 sq ft | 24,000 |
| 1,500–2,000 sq ft | 30,000 |
| 2,000–2,500 sq ft | 34,000 |
Then come the adjustments. The first four are ENERGY STAR’s own; the rest are standard practice in rule-of-thumb load estimates, and we state the factor we use for each.
- Shade and sun. A heavily shaded room needs about 10 percent less. A room that gets strong afternoon sun needs about 10 percent more. West-facing rooms with big windows are the classic case.
- Occupants. Each person beyond two adds about 600 BTU. A home office for one doesn’t need this; a family room that holds six on movie night does.
- Kitchens. Add 4,000 BTU. Ovens and ranges are heat sources, and open-plan homes concentrate them in the kitchen.
- Ceiling height. The table assumes 8 ft. We scale by the actual height, because the unit conditions a volume of air, not a floor. A 10 ft ceiling adds 25 percent.
- Insulation. Poor insulation (an older house with little attic insulation, single-pane windows, a garage) adds 20 percent. Good insulation (a recent build, new windows) takes 10 percent off.
- Climate. Hot and dry climates add 10 percent; hot and humid ones add 15 percent, because the latent (moisture) load is hard work for the coil. Cold climates add 20 percent for a different reason: there the heating load decides the size, and you should be reading the unit’s heating capacity at 5°F rather than its nameplate cooling number.
- Room type. Garages add 15 percent for door and slab losses. Sunrooms add 20 percent for the glass. Basements take 15 percent off, because earth-cooled walls carry much of the load, and oversizing a basement unit is how you end up with a damp one.
Last, we round up to the nearest capacity that’s sold: 6,000, 9,000, 12,000, 18,000, 24,000, 30,000 or 36,000 BTU. There’s a 5 percent grace, so a 12,500 BTU load lands on a 12,000 BTU unit instead of jumping to 18,000; a modern inverter unit covers that comfortably.
When you’re on the line between two sizes
The calculator flags it when your load sits within a few hundred BTU of a boundary. When that happens, work through these in order:
- Which way does the room face? West and south windows push you up. North-facing or shaded, stay down.
- How tight is the house? Drafty, older, single-pane: up. Newer, foam-sealed, double-pane: down.
- What’s the room for? A bedroom you want quiet at night: stay down, because a smaller unit on a lower fan speed is quieter and dehumidifies better. A living room that fills with people and a TV: up.
- Heating in a cold climate? Up, and check the heating capacity table at your design temperature.
Still can’t decide? Pick the smaller one, for the humidity reason above.
Sizing a multi-zone system
Multi-zone systems get sized twice. Each room gets its own head, sized exactly as above. The outdoor unit is rated by total capacity, and there’s a quirk: most manufacturers let the heads add up to 20 to 30 percent more than the outdoor unit’s rating, on the assumption that not every room peaks at once. So a 9,000 + 9,000 + 12,000 set of heads (30,000 total) often pairs with a 24,000 or 27,000 BTU outdoor unit.
The calculator gives you the per-room number. For the outdoor unit, read the manufacturer’s combination table for the specific system; our 2-zone and 3-zone guides walk through examples.
What this calculator isn’t
It isn’t a Manual J. A Manual J load calculation accounts for window area and orientation, wall construction, air infiltration, internal gains and your local design temperatures, room by room. It’s the right tool for a whole-house system, and a reputable installer will run one (or should) before quoting a multi-zone job. If a contractor sizes your whole house from square footage alone, get another quote.
For a single room, which is what most mini splits are bought for, this method gets it right the overwhelming majority of the time. We’d rather you spend thirty seconds here and reach the size page knowing why the number is what it is than spend an evening reading forum threads about someone else’s room.
Questions people ask
How many BTU per square foot for a mini split?
About 20 to 25 BTU per square foot with 8 ft ceilings, average insulation and mixed sun. Sunny rooms, kitchens, garages and poorly insulated spaces need more; shaded rooms and basements need less. The calculator applies each of those adjustments and shows them.
What size mini split for a 500 sq ft room?
Usually 12,000 BTU. Push to 18,000 BTU only if the room is a kitchen, has a vaulted ceiling, bakes in afternoon sun, or you're in a hot-humid or cold climate where heating load leads.
What size mini split for 1,000 sq ft?
An open 1,000 sq ft space lands around 18,000 to 24,000 BTU. If that 1,000 sq ft is three rooms with doors, you need two or three indoor heads, not one bigger unit.
Is it better to oversize or undersize a mini split?
Neither, but oversizing is the more common and more annoying mistake: the unit cools the air quickly, shuts off before it has removed the humidity, and leaves the room cold and damp. If you're stuck between two sizes, use the tie-breakers on this page rather than defaulting to the bigger one.
Is this the same as a Manual J calculation?
No. A Manual J is a room-by-room heat load calculation that accounts for window area, orientation, infiltration and construction details. This calculator is a planning estimate that gets single rooms right the vast majority of the time. For a whole-house multi-zone system, pay for a Manual J.